diff options
author | Antonio Borneo <borneo.antonio@gmail.com> | 2019-04-03 10:37:24 +0200 |
---|---|---|
committer | Tomas Vanek <vanekt@fbl.cz> | 2019-05-14 19:37:11 +0100 |
commit | 6cb5ba6f1136df2986850f5c176cb38e34ca1795 (patch) | |
tree | 0cbc15e5119fe4d60760cd2cff7c13834c92942c /src/flash/nor/lpc2000.c | |
parent | 69165509386efffc2848ac3b345be750f1ddbe56 (diff) |
helper/command: change prototype of command_print/command_print_sameline
To prepare for handling TCL return values consistently, all calls
to command_print/command_print_sameline should switch to CMD as
first parameter.
Change prototype of command_print() and command_print_sameline()
to pass CMD instead of CMD_CTX.
Since the first parameter is currently not used, the change can be
done though scripts without manual coding.
This patch is created using the command:
sed -i PATTERN $(find src/ doc/ -type f)
with all the following patters:
's/\(command_print(cmd\)->ctx,/\1,/'
's/\(command_print(CMD\)_CTX,/\1,/'
's/\(command_print(struct command_\)context \*context,/\1invocation *cmd,/'
's/\(command_print_sameline(cmd\)->ctx,/\1,/'
's/\(command_print_sameline(CMD\)_CTX,/\1,/'
's/\(command_print_sameline(struct command_\)context \*context,/\1invocation *cmd,/'
This change is inspired by http://openocd.zylin.com/1815 from Paul
Fertser but is now done through scripting.
Change-Id: I3386d8f96cdc477e7a2308dd18269de3bed04385
Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com>
Signed-off-by: Paul Fertser <fercerpav@gmail.com>
Reviewed-on: http://openocd.zylin.com/5081
Tested-by: jenkins
Reviewed-by: Tomas Vanek <vanekt@fbl.cz>
Diffstat (limited to 'src/flash/nor/lpc2000.c')
-rw-r--r-- | src/flash/nor/lpc2000.c | 6 |
1 files changed, 3 insertions, 3 deletions
diff --git a/src/flash/nor/lpc2000.c b/src/flash/nor/lpc2000.c index cb3f58e8..2a69af69 100644 --- a/src/flash/nor/lpc2000.c +++ b/src/flash/nor/lpc2000.c @@ -1579,11 +1579,11 @@ COMMAND_HANDLER(lpc2000_handle_part_id_command) int status_code = get_lpc2000_part_id(bank, &part_id); if (status_code != 0x0) { if (status_code == ERROR_FLASH_OPERATION_FAILED) { - command_print(CMD_CTX, "no sufficient working area specified, can't access LPC2000 IAP interface"); + command_print(CMD, "no sufficient working area specified, can't access LPC2000 IAP interface"); } else - command_print(CMD_CTX, "lpc2000 IAP returned status code %i", status_code); + command_print(CMD, "lpc2000 IAP returned status code %i", status_code); } else - command_print(CMD_CTX, "lpc2000 part id: 0x%8.8" PRIx32, part_id); + command_print(CMD, "lpc2000 part id: 0x%8.8" PRIx32, part_id); return retval; } |