aboutsummaryrefslogtreecommitdiff
path: root/src/flash/nor/lpc2000.c
diff options
context:
space:
mode:
authorAntonio Borneo <borneo.antonio@gmail.com>2019-04-03 10:37:24 +0200
committerTomas Vanek <vanekt@fbl.cz>2019-05-14 19:37:11 +0100
commit6cb5ba6f1136df2986850f5c176cb38e34ca1795 (patch)
tree0cbc15e5119fe4d60760cd2cff7c13834c92942c /src/flash/nor/lpc2000.c
parent69165509386efffc2848ac3b345be750f1ddbe56 (diff)
helper/command: change prototype of command_print/command_print_sameline
To prepare for handling TCL return values consistently, all calls to command_print/command_print_sameline should switch to CMD as first parameter. Change prototype of command_print() and command_print_sameline() to pass CMD instead of CMD_CTX. Since the first parameter is currently not used, the change can be done though scripts without manual coding. This patch is created using the command: sed -i PATTERN $(find src/ doc/ -type f) with all the following patters: 's/\(command_print(cmd\)->ctx,/\1,/' 's/\(command_print(CMD\)_CTX,/\1,/' 's/\(command_print(struct command_\)context \*context,/\1invocation *cmd,/' 's/\(command_print_sameline(cmd\)->ctx,/\1,/' 's/\(command_print_sameline(CMD\)_CTX,/\1,/' 's/\(command_print_sameline(struct command_\)context \*context,/\1invocation *cmd,/' This change is inspired by http://openocd.zylin.com/1815 from Paul Fertser but is now done through scripting. Change-Id: I3386d8f96cdc477e7a2308dd18269de3bed04385 Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com> Signed-off-by: Paul Fertser <fercerpav@gmail.com> Reviewed-on: http://openocd.zylin.com/5081 Tested-by: jenkins Reviewed-by: Tomas Vanek <vanekt@fbl.cz>
Diffstat (limited to 'src/flash/nor/lpc2000.c')
-rw-r--r--src/flash/nor/lpc2000.c6
1 files changed, 3 insertions, 3 deletions
diff --git a/src/flash/nor/lpc2000.c b/src/flash/nor/lpc2000.c
index cb3f58e8..2a69af69 100644
--- a/src/flash/nor/lpc2000.c
+++ b/src/flash/nor/lpc2000.c
@@ -1579,11 +1579,11 @@ COMMAND_HANDLER(lpc2000_handle_part_id_command)
int status_code = get_lpc2000_part_id(bank, &part_id);
if (status_code != 0x0) {
if (status_code == ERROR_FLASH_OPERATION_FAILED) {
- command_print(CMD_CTX, "no sufficient working area specified, can't access LPC2000 IAP interface");
+ command_print(CMD, "no sufficient working area specified, can't access LPC2000 IAP interface");
} else
- command_print(CMD_CTX, "lpc2000 IAP returned status code %i", status_code);
+ command_print(CMD, "lpc2000 IAP returned status code %i", status_code);
} else
- command_print(CMD_CTX, "lpc2000 part id: 0x%8.8" PRIx32, part_id);
+ command_print(CMD, "lpc2000 part id: 0x%8.8" PRIx32, part_id);
return retval;
}