aboutsummaryrefslogtreecommitdiff
path: root/drivers/scsi/bfa/include/defs/bfa_defs_status.h
blob: 6eb4e62096fce1334883745a85c82ea71891a0db (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
/*
 * Copyright (c) 2005-2009 Brocade Communications Systems, Inc.
 * All rights reserved
 * www.brocade.com
 *
 * Linux driver for Brocade Fibre Channel Host Bus Adapter.
 *
 * This program is free software; you can redistribute it and/or modify it
 * under the terms of the GNU General Public License (GPL) Version 2 as
 * published by the Free Software Foundation
 *
 * This program is distributed in the hope that it will be useful, but
 * WITHOUT ANY WARRANTY; without even the implied warranty of
 * MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.  See the GNU
 * General Public License for more details.
 */
#ifndef __BFA_DEFS_STATUS_H__
#define __BFA_DEFS_STATUS_H__

/**
 * API status return values
 *
 * NOTE: The error msgs are auto generated from the comments. Only singe line
 * comments are supported
 */
enum bfa_status {
	BFA_STATUS_OK 		= 0,	/*  Success */
	BFA_STATUS_FAILED 	= 1,	/*  Operation failed */
	BFA_STATUS_EINVAL 	= 2,	/*  Invalid params Check input
					 * parameters */
	BFA_STATUS_ENOMEM 	= 3,	/*  Out of resources */
	BFA_STATUS_ENOSYS 	= 4,	/*  Function not implemented */
	BFA_STATUS_ETIMER 	= 5,	/*  Timer expired - Retry, if
					 * persists, contact support */
	BFA_STATUS_EPROTOCOL 	= 6,	/*  Protocol error */
	BFA_STATUS_ENOFCPORTS 	= 7,	/*  No FC ports resources */
	BFA_STATUS_NOFLASH 	= 8,	/*  Flash not present */
	BFA_STATUS_BADFLASH 	= 9,	/*  Flash is corrupted or bad */
	BFA_STATUS_SFP_UNSUPP 	= 10,	/*  Unsupported SFP - Replace SFP */
	BFA_STATUS_UNKNOWN_VFID = 11,	/*  VF_ID not found */
	BFA_STATUS_DATACORRUPTED = 12,	/*  Diag returned data corrupted
					 * contact support */
	BFA_STATUS_DEVBUSY 	= 13,	/*  Device busy - Retry operation */
	BFA_STATUS_ABORTED 	= 14,	/*  Operation aborted */
	BFA_STATUS_NODEV 	= 15,	/*  Dev is not present */
	BFA_STATUS_HDMA_FAILED 	= 16,	/*  Host dma failed contact support */
	BFA_STATUS_FLASH_BAD_LEN = 17,	/*  Flash bad length */
	BFA_STATUS_UNKNOWN_LWWN = 18,	/*  LPORT PWWN not found */
	BFA_STATUS_UNKNOWN_RWWN = 19,	/*  RPORT PWWN not found */
	BFA_STATUS_FCPT_LS_RJT 	= 20,	/*  Got LS_RJT for FC Pass
					 * through Req */
	BFA_STATUS_VPORT_EXISTS = 21,	/*  VPORT already exists */
	BFA_STATUS_VPORT_MAX 	= 22,	/*  Reached max VPORT supported
					 * limit */
	BFA_STATUS_UNSUPP_SPEED = 23,	/*  Invalid Speed Check speed
					 * setting */
	BFA_STATUS_INVLD_DFSZ 	= 24,	/*  Invalid Max data field size */
	BFA_STATUS_CNFG_FAILED 	= 25,	/*  Setting can not be persisted */
	BFA_STATUS_CMD_NOTSUPP 	= 26,	/*  Command/API not supported */
	BFA_STATUS_NO_ADAPTER 	= 27,	/*  No Brocade Adapter Found */
	BFA_STATUS_LINKDOWN 	= 28,	/*  Link is down - Check or replace
					 * SFP/cable */
	BFA_STATUS_FABRIC_RJT 	= 29,	/*  Reject from attached fabric */
	BFA_STATUS_UNKNOWN_VWWN = 30,	/*  VPORT PWWN not found */
	BFA_STATUS_NSLOGIN_FAILED = 31,	/*  Nameserver login failed */
	BFA_STATUS_NO_RPORTS 	= 32,	/*  No remote ports found */
	BFA_STATUS_NSQUERY_FAILED = 33,	/*  Nameserver query failed */
	BFA_STATUS_PORT_OFFLINE = 34,	/*  Port is not online */
	BFA_STATUS_RPORT_OFFLINE = 35,	/*  RPORT is not online */
	BFA_STATUS_TGTOPEN_FAILED = 36,	/*  Remote SCSI target open failed */
	BFA_STATUS_BAD_LUNS 	= 37,	/*  No valid LUNs found */
	BFA_STATUS_IO_FAILURE 	= 38,	/*  SCSI target IO failure */
	BFA_STATUS_NO_FABRIC 	= 39,	/*  No switched fabric present */
	BFA_STATUS_EBADF 	= 40,	/*  Bad file descriptor */
	BFA_STATUS_EINTR 	= 41,	/*  A signal was caught during ioctl */
	BFA_STATUS_EIO 		= 42,	/*  I/O error */
	BFA_STATUS_ENOTTY 	= 43,	/*  Inappropriate I/O control
					 * operation */
	BFA_STATUS_ENXIO 	= 44,	/*  No such device or address */
	BFA_STATUS_EFOPEN 	= 45,	/*  Failed to open file */
	BFA_STATUS_VPORT_WWN_BP = 46,	/*  WWN is same as base port's WWN */
	BFA_STATUS_PORT_NOT_DISABLED = 47, /*  Port not disabled disable port
					    * first */
	BFA_STATUS_BADFRMHDR 	= 48,	/*  Bad frame header */
	BFA_STATUS_BADFRMSZ 	= 49,	/*  Bad frame size check and replace
					 * SFP/cable */
	BFA_STATUS_MISSINGFRM 	= 50,   /* Missing frame check and replace
					 * SFP/cable or for Mezz card check and
					 * replace pass through module */
	BFA_STATUS_LINKTIMEOUT 	= 51,	/*  Link timeout check and replace
					 * SFP/cable */
	BFA_STATUS_NO_FCPIM_NEXUS = 52,	/*  No FCP Nexus exists with the
					 * rport */
	BFA_STATUS_CHECKSUM_FAIL = 53,	/*  checksum failure */
	BFA_STATUS_GZME_FAILED 	= 54,	/*  Get zone member query failed */
	BFA_STATUS_SCSISTART_REQD = 55,	/*  SCSI disk require START command */
	BFA_STATUS_IOC_FAILURE 	= 56,	/*  IOC failure - Retry, if persists
					 * contact support */
	BFA_STATUS_INVALID_WWN 	= 57,	/*  Invalid WWN */
	BFA_STATUS_MISMATCH 	= 58,	/*  Version mismatch */
	BFA_STATUS_IOC_ENABLED 	= 59,	/*  IOC is already enabled */
	BFA_STATUS_ADAPTER_ENABLED = 60, /*  Adapter is not disabled disable
					  * adapter first */
	BFA_STATUS_IOC_NON_OP 	= 61,	/*  IOC is not operational. Enable IOC
					 * and if it still fails,
					 * contact support */
	BFA_STATUS_ADDR_MAP_FAILURE = 62, /*  PCI base address not mapped
					   * in OS */
	BFA_STATUS_SAME_NAME 	= 63,	/*  Name exists! use a different
					 * name */
	BFA_STATUS_PENDING      = 64,   /*  API completes asynchronously */
	BFA_STATUS_8G_SPD	= 65,	/*  Speed setting not valid for
					 * 8G HBA */
	BFA_STATUS_4G_SPD	= 66,	/*  Speed setting not valid for
					 * 4G HBA */
	BFA_STATUS_AD_IS_ENABLE = 67,	/*  Adapter is already enabled */
	BFA_STATUS_EINVAL_TOV 	= 68,	/*  Invalid path failover TOV */
	BFA_STATUS_EINVAL_QDEPTH = 69,	/*  Invalid queue depth value */
	BFA_STATUS_VERSION_FAIL = 70,	/*  Application/Driver version
					 * mismatch */
	BFA_STATUS_DIAG_BUSY    = 71,	/*  diag busy */
	BFA_STATUS_BEACON_ON	= 72,	/*  Port Beacon already on */
	BFA_STATUS_BEACON_OFF	= 73,	/*  Port Beacon already off */
	BFA_STATUS_LBEACON_ON   = 74,	/*  Link End-to-End Beacon already
					 * on */
	BFA_STATUS_LBEACON_OFF	= 75,	/*  Link End-to-End Beacon already
					 * off */
	BFA_STATUS_PORT_NOT_INITED = 76, /*  Port not initialized */
	BFA_STATUS_RPSC_ENABLED = 77, /*  Target has a valid speed */
	BFA_STATUS_ENOFSAVE = 78,	/*  No saved firmware trace */
	BFA_STATUS_BAD_FILE = 79,	/*  Not a valid Brocade Boot Code
					 * file */
	BFA_STATUS_RLIM_EN = 80,	/*  Target rate limiting is already
					 * enabled */
	BFA_STATUS_RLIM_DIS = 81,  /*  Target rate limiting is already
				    * disabled */
	BFA_STATUS_IOC_DISABLED = 82,   /*  IOC is already disabled */
	BFA_STATUS_ADAPTER_DISABLED = 83,   /*  Adapter is already disabled */
	BFA_STATUS_BIOS_DISABLED = 84,   /*  Bios is already disabled */
	BFA_STATUS_AUTH_ENABLED = 85,   /*  Authentication is already
					 * enabled */
	BFA_STATUS_AUTH_DISABLED = 86,   /*  Authentication is already
					 * disabled */
	BFA_STATUS_ERROR_TRL_ENABLED = 87,   /*  Target rate limiting is
					      * enabled */
	BFA_STATUS_ERROR_QOS_ENABLED = 88,   /*  QoS is enabled */
	BFA_STATUS_NO_SFP_DEV = 89, /*  No SFP device check or replace SFP */
	BFA_STATUS_MEMTEST_FAILED = 90,	/*  Memory test failed contact
					 * support */
	BFA_STATUS_INVALID_DEVID = 91,	/*  Invalid device id provided */
	BFA_STATUS_QOS_ENABLED = 92, /*  QOS is already enabled */
	BFA_STATUS_QOS_DISABLED = 93, /*  QOS is already disabled */
	BFA_STATUS_INCORRECT_DRV_CONFIG = 94, /*  Check configuration
					       * key/value pair */
	BFA_STATUS_REG_FAIL = 95, /*  Can't read windows registry */
	BFA_STATUS_IM_INV_CODE = 96, /*  Invalid IOCTL code */
	BFA_STATUS_IM_INV_VLAN = 97, /*  Invalid VLAN ID */
	BFA_STATUS_IM_INV_ADAPT_NAME = 98, /*  Invalid adapter name */
	BFA_STATUS_IM_LOW_RESOURCES = 99, /*  Memory allocation failure in
					   * driver */
	BFA_STATUS_IM_VLANID_IS_PVID = 100, /*  Given VLAN id same as PVID */
	BFA_STATUS_IM_VLANID_EXISTS = 101, /*  Given VLAN id already exists */
	BFA_STATUS_IM_FW_UPDATE_FAIL = 102, /*  Updating firmware with new
					     * VLAN ID failed */
	BFA_STATUS_PORTLOG_ENABLED = 103, /*  Port Log is already enabled */
	BFA_STATUS_PORTLOG_DISABLED = 104, /*  Port Log is already disabled */
	BFA_STATUS_FILE_NOT_FOUND = 105, /*  Specified file could not be
					  * found */
	BFA_STATUS_QOS_FC_ONLY = 106, /*  QOS can be enabled for FC mode
				       * only */
	BFA_STATUS_RLIM_FC_ONLY = 107, /*  RATELIM can be enabled for FC mode
					* only */
	BFA_STATUS_CT_SPD = 108, /*  Invalid speed selection for Catapult. */
	BFA_STATUS_LEDTEST_OP = 109, /*  LED test is operating */
	BFA_STATUS_CEE_NOT_DN = 110, /*  eth port is not at down state, please
				      * bring down first */
	BFA_STATUS_10G_SPD = 111, /*  Speed setting not valid for 10G CNA */
	BFA_STATUS_IM_INV_TEAM_NAME = 112, /*  Invalid team name */
	BFA_STATUS_IM_DUP_TEAM_NAME = 113, /*  Given team name already
					    * exists */
	BFA_STATUS_IM_ADAPT_ALREADY_IN_TEAM = 114, /*  Given adapter is part
						    * of another team */
	BFA_STATUS_IM_ADAPT_HAS_VLANS = 115, /*  Adapter has VLANs configured.
					      * Delete all VLANs to become
					      * part of the team */
	BFA_STATUS_IM_PVID_MISMATCH = 116, /*  Mismatching PVIDs configured
					    * for adapters */
	BFA_STATUS_IM_LINK_SPEED_MISMATCH = 117, /*  Mismatching link speeds
						  * configured for adapters */
	BFA_STATUS_IM_MTU_MISMATCH = 118, /*  Mismatching MTUs configured for
					   * adapters */
	BFA_STATUS_IM_RSS_MISMATCH = 119, /*  Mismatching RSS parameters
					   * configured for adapters */
	BFA_STATUS_IM_HDS_MISMATCH = 120, /*  Mismatching HDS parameters
					   * configured for adapters */
	BFA_STATUS_IM_OFFLOAD_MISMATCH = 121, /*  Mismatching offload
					       * parameters configured for
					       * adapters */
	BFA_STATUS_IM_PORT_PARAMS = 122, /*  Error setting port parameters */
	BFA_STATUS_IM_PORT_NOT_IN_TEAM = 123, /*  Port is not part of team */
	BFA_STATUS_IM_CANNOT_REM_PRI = 124, /*  Primary adapter cannot be
					     * removed. Change primary before
					     * removing */
	BFA_STATUS_IM_MAX_PORTS_REACHED = 125, /*  Exceeding maximum ports
						* per team */
	BFA_STATUS_IM_LAST_PORT_DELETE = 126, /*  Last port in team being
					       * deleted */
	BFA_STATUS_IM_NO_DRIVER = 127, /*  IM driver is not installed */
	BFA_STATUS_IM_MAX_VLANS_REACHED = 128, /*  Exceeding maximum VLANs
						* per port */
	BFA_STATUS_TOMCAT_SPD_NOT_ALLOWED = 129, /* Bios speed config not
						  * allowed for CNA */
	BFA_STATUS_NO_MINPORT_DRIVER = 130, /*  Miniport driver is not
					     * loaded */
	BFA_STATUS_CARD_TYPE_MISMATCH = 131, /*  Card type mismatch */
	BFA_STATUS_BAD_ASICBLK = 132, /*  Bad ASIC block */
	BFA_STATUS_NO_DRIVER = 133, /*  Brocade adapter/driver not installed
				     *  or loaded */
	BFA_STATUS_INVALID_MAC = 134, /*  Invalid MAC address */
	BFA_STATUS_IM_NO_VLAN = 135, /*  No VLANs configured on the adapter */
	BFA_STATUS_IM_ETH_LB_FAILED = 136, /*  Ethernet loopback test failed */
	BFA_STATUS_IM_PVID_REMOVE = 137, /* Cannot remove port VLAN (PVID) */
	BFA_STATUS_IM_PVID_EDIT = 138, /* Cannot edit port VLAN (PVID) */
	BFA_STATUS_CNA_NO_BOOT = 139, /*  Boot upload not allowed for CNA */
	BFA_STATUS_IM_PVID_NON_ZERO = 140, /*  Port VLAN ID (PVID) is Set to
					    * Non-Zero Value */
	BFA_STATUS_IM_INETCFG_LOCK_FAILED = 141, /*  Acquiring Network
						  * Subsystem Lock Failed.Please
						  * try after some time */
	BFA_STATUS_IM_GET_INETCFG_FAILED = 142, /*  Acquiring Network Subsystem
						 * handle Failed. Please try
						 * after some time */
	BFA_STATUS_IM_NOT_BOUND = 143, /*  IM driver is not active */
	BFA_STATUS_INSUFFICIENT_PERMS = 144, /*  User doesn't have sufficient
					      * permissions to execute the BCU
					      * application */
	BFA_STATUS_IM_INV_VLAN_NAME = 145, /* Invalid/Reserved VLAN name
					    * string. The name is not allowed
					    * for the normal VLAN */
	BFA_STATUS_CMD_NOTSUPP_CNA = 146, /*  Command not supported for CNA */
	BFA_STATUS_IM_PASSTHRU_EDIT = 147, /* Can not edit passthrough VLAN
					    * id */
	BFA_STATUS_IM_BIND_FAILED = 148, /* IM Driver bind operation
					  * failed */
	BFA_STATUS_IM_UNBIND_FAILED = 149, /* IM Driver unbind operation
					    * failed */
	BFA_STATUS_IM_PORT_IN_TEAM = 150, /*  Port is already part of the
					   * team */
	BFA_STATUS_IM_VLAN_NOT_FOUND = 151, /*  VLAN ID doesn't exists */
	BFA_STATUS_IM_TEAM_NOT_FOUND = 152, /*  Teaming configuration doesn't
					     * exists */
	BFA_STATUS_IM_TEAM_CFG_NOT_ALLOWED = 153, /*  Given settings are not
						* allowed for the current
						* Teaming mode */
	BFA_STATUS_PBC = 154, /* Operation not allowed for pre-boot
			       * configuration */
	BFA_STATUS_DEVID_MISSING = 155, /* Boot image is not for the adapter(s)
					 * installed */
	BFA_STATUS_BAD_FWCFG = 156, /* Bad firmware configuration */
	BFA_STATUS_CREATE_FILE = 157, /* Failed to create temporary file */
	BFA_STATUS_INVALID_VENDOR = 158, /* Invalid switch vendor */
	BFA_STATUS_SFP_NOT_READY = 159, /* SFP info is not ready. Retry */
	BFA_STATUS_NO_TOPOLOGY_FOR_CNA = 160, /* Topology command not
					       * applicable to CNA */
	BFA_STATUS_BOOT_CODE_UPDATED = 161, /* reboot -- -r is needed after
					     * boot code updated */
	BFA_STATUS_BOOT_VERSION = 162, /* Boot code version not compatible with
					* the driver installed */
	BFA_STATUS_CARDTYPE_MISSING = 163, /* Boot image is not for the
					    * adapter(s) installed */
	BFA_STATUS_INVALID_CARDTYPE = 164, /* Invalid card type provided */
	BFA_STATUS_MAX_VAL              /* Unknown error code */
};
#define bfa_status_t enum bfa_status