From 5cfb22a1f83e4f04c0a4df89b60053a077222e2b Mon Sep 17 00:00:00 2001 From: NeilBrown Date: Tue, 3 Jul 2012 11:46:53 +1000 Subject: md/raid5: prefer replacing failed devices over want-replacement devices. If a RAID5 has both a failed device and a device marked as 'WantReplacement', then we should preferentially replace the failed device. However the current code replaces whichever is found first. So split into 2 loops, check fail failed/missing first, and only check for WantReplacement if nothing is failed or missing. Reported-by: majianpeng Signed-off-by: NeilBrown --- drivers/md/raid5.c | 13 ++++++++----- 1 file changed, 8 insertions(+), 5 deletions(-) (limited to 'drivers/md') diff --git a/drivers/md/raid5.c b/drivers/md/raid5.c index d26767246d2..95fcbbf3d6c 100644 --- a/drivers/md/raid5.c +++ b/drivers/md/raid5.c @@ -5465,10 +5465,9 @@ static int raid5_add_disk(struct mddev *mddev, struct md_rdev *rdev) if (rdev->saved_raid_disk >= 0 && rdev->saved_raid_disk >= first && conf->disks[rdev->saved_raid_disk].rdev == NULL) - disk = rdev->saved_raid_disk; - else - disk = first; - for ( ; disk <= last ; disk++) { + first = rdev->saved_raid_disk; + + for (disk = first; disk <= last; disk++) { p = conf->disks + disk; if (p->rdev == NULL) { clear_bit(In_sync, &rdev->flags); @@ -5477,8 +5476,11 @@ static int raid5_add_disk(struct mddev *mddev, struct md_rdev *rdev) if (rdev->saved_raid_disk != disk) conf->fullsync = 1; rcu_assign_pointer(p->rdev, rdev); - break; + goto out; } + } + for (disk = first; disk <= last; disk++) { + p = conf->disks + disk; if (test_bit(WantReplacement, &p->rdev->flags) && p->replacement == NULL) { clear_bit(In_sync, &rdev->flags); @@ -5490,6 +5492,7 @@ static int raid5_add_disk(struct mddev *mddev, struct md_rdev *rdev) break; } } +out: print_raid5_conf(conf); return err; } -- cgit v1.2.3-18-g5258