Age | Commit message (Collapse) | Author |
|
By changing field ordering we can avoid a couple of memory holes in
the tables that use the ibmvfc_async_desc structure.
Signed-off-by: Robert Jennings <rcj@linux.vnet.ibm.com>
Acked-by: Brian King <brking@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
By default, ibmvfc does not log any async events in order
to avoid flooding the log with them. Improve on this by
logging by default events that are not likely to flood the
log, such as link up/down. Having these events in the log
will improve the ability to debug issues with ibmvfc.
Signed-off-by: Brian King <brking@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
Bump driver version.
Signed-off-by: Brian King <brking@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
The ibmvfc driver was incorrectly obtaining a scsi_target pointer
from an fc_rport. The way it is coded ensures that ibmvfc's
terminate_rport_io handler does absolutely nothing. Fix this up
to iterate through affected devices differently, sending cancel
and abort task set as appropriate. Without this patch,
fast_io_fail_tmo is broken for ibmvfc.
Signed-off-by: Brian King <brking@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
Commit 43c8da907ccc656935d1085701f4db83385d8a59 introduced a race
condition which can occur when adding/deleting rports. There are
two possible threads now that can be deleting rports in the ibmvfc
driver, which can result in list_del being called twice, resulting
in an oops. This patch adds a new state to the ibmvfc_target struct
to indicate the target has been removed from the list and is in
the process of being deleted.
Signed-off-by: Brian King <brking@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
Bump driver version.
Signed-off-by: Brian King <brking@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
This fixes a softlockup seen on resume. During resume, the CRQ
must be reenabled. However, the H_ENABLE_CRQ hcall used to do
this may return H_BUSY or H_LONG_BUSY. When this happens, the
caller is expected to retry later. Normally the H_ENABLE_CRQ
succeeds relatively soon. However, we have seen cases where
this can take long enough to see softlockup warnings.
This patch changes a simple loop, which was causing the
softlockup, to a loop at task level which sleeps between
retries rather than simply spinning.
Signed-off-by: Brian King <brking@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
If a command times out resulting in EH getting invoked, we wait for the
aborted commands to come back after sending the abort. Shorten
the amount of time we wait for these responses, to ensure we don't
get stuck in EH for several minutes.
Signed-off-by: Brian King <brking@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
Bump driver version to 1.0.7.
Signed-off-by: Brian King <brking@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
Adds support for FC passthru via BSG.
Signed-off-by: Brian King <brking@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
|
|
Fixes a problem seen where sending a PRLI to a target
resulted in it sending a LOGO. This caused the ibmvfc
driver to go back through discovery again, which caused
another PRLI attempt, which caused another LOGO. Fix this
behavior by ignoring LOGO if we haven't even logged into
the target yet.
Signed-off-by: Brian King <brking@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
|
|
Bump driver version
Signed-off-by: Brian King <brking@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
|
|
The virtual I/O server controlling the NPIV adapter associated with
a virtual fibre channel adapter can send a HALT event to the client.
When this occurs, the client can no longer send commands until a RESUME
is received. By adding support for flush on halt, we will get all of
our outstanding commands flushed back before the Virtual I/O server
enters the halt state, eliminating potential command timeouts for
outstanding commands which might occur if we did not support this feature.
Signed-off-by: Brian King <brking@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
|
|
This patch adds support for a new command supported by the Virtual I/O
Server, NPIV Logout. The command will abort all outstanding commands
and log out of the fabric. Currently, the only way to do this is
by breaking the CRQ, which can take a fairly long time when lots of
commands are outstanding. The NPIV Logout commands provides a mechanism
to accomplish virtually the same function, but is much faster.
Signed-off-by: Brian King <brking@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
|
|
Fixes the following deadlock scenario shown below. We currently allow
queuecommand to send commands when the ibmvfc workqueue is scanning for
new rports, so we should also allow EH to function at this time as well.
scsi_eh_3 D 0000000000000000 12304 1279 2
Call Trace:
[c0000002f7257730] [c0000002f72577e0] 0xc0000002f72577e0 (unreliable)
[c0000002f7257900] [c0000000000118f4] .__switch_to+0x158/0x1a0
[c0000002f72579a0] [c0000000004f8b40] .schedule+0x8d4/0x9dc
[c0000002f7257b60] [c0000000004f8f08] .schedule_timeout+0xa8/0xe8
[c0000002f7257c50] [d0000000001d23e0] .ibmvfc_wait_while_resetting+0xe4/0x140 [ibmvfc]
[c0000002f7257d20] [d0000000001d3984] .ibmvfc_eh_abort_handler+0x60/0xe4 [ibmvfc]
[c0000002f7257dc0] [d000000000366714] .scsi_error_handler+0x38c/0x674 [scsi_mod]
[c0000002f7257f00] [c0000000000a7470] .kthread+0x78/0xc4
[c0000002f7257f90] [c000000000029b8c] .kernel_thread+0x4c/0x68
ibmvfc_3 D 0000000000000000 12432 1280 2
Call Trace:
[c0000002f7253540] [c0000002f72535f0] 0xc0000002f72535f0 (unreliable)
[c0000002f7253710] [c0000000000118f4] .__switch_to+0x158/0x1a0
[c0000002f72537b0] [c0000000004f8b40] .schedule+0x8d4/0x9dc
[c0000002f7253970] [c0000000004f8e98] .schedule_timeout+0x38/0xe8
[c0000002f7253a60] [c0000000004f80cc] .wait_for_common+0x138/0x220
[c0000002f7253b40] [c0000000000a2784] .flush_cpu_workqueue+0xac/0xcc
[c0000002f7253c10] [c0000000000a2960] .flush_workqueue+0x58/0xa0
[c0000002f7253ca0] [d0000000000827fc] .fc_flush_work+0x4c/0x64 [scsi_transport_fc]
[c0000002f7253d20] [d000000000082db4] .fc_remote_port_add+0x48/0x6c4 [scsi_transport_fc]
[c0000002f7253dd0] [d0000000001d7d04] .ibmvfc_work+0x820/0xa7c [ibmvfc]
[c0000002f7253f00] [c0000000000a7470] .kthread+0x78/0xc4
[c0000002f7253f90] [c000000000029b8c] .kernel_thread+0x4c/0x68
fc_wq_3 D 0000000000000000 10720 1283 2
Call Trace:
[c0000002f559ac30] [c0000002f559ace0] 0xc0000002f559ace0 (unreliable)
[c0000002f559ae00] [c0000000000118f4] .__switch_to+0x158/0x1a0
[c0000002f559aea0] [c0000000004f8b40] .schedule+0x8d4/0x9dc
[c0000002f559b060] [c0000000004f8e98] .schedule_timeout+0x38/0xe8
[c0000002f559b150] [c0000000004f80cc] .wait_for_common+0x138/0x220
[c0000002f559b230] [c0000000002721c4] .blk_execute_rq+0xb4/0x100
[c0000002f559b360] [d00000000036a1f8] .scsi_execute+0x118/0x194 [scsi_mod]
[c0000002f559b420] [d00000000036a32c] .scsi_execute_req+0xb8/0x124 [scsi_mod]
[c0000002f559b500] [d0000000000c1330] .sd_sync_cache+0x8c/0x108 [sd_mod]
[c0000002f559b5e0] [d0000000000c15b4] .sd_shutdown+0x9c/0x158 [sd_mod]
[c0000002f559b660] [d0000000000c16d0] .sd_remove+0x60/0xb4 [sd_mod]
[c0000002f559b700] [c000000000392ecc] .__device_release_driver+0xd0/0x118
[c0000002f559b7a0] [c000000000393080] .device_release_driver+0x30/0x54
[c0000002f559b830] [c000000000392108] .bus_remove_device+0x128/0x16c
[c0000002f559b8d0] [c00000000038f94c] .device_del+0x158/0x234
[c0000002f559b960] [d00000000036f078] .__scsi_remove_device+0x5c/0xd4 [scsi_mod]
[c0000002f559b9f0] [d00000000036f124] .scsi_remove_device+0x34/0x58 [scsi_mod]
[c0000002f559ba80] [d00000000036f204] .__scsi_remove_target+0xb4/0x120 [scsi_mod]
[c0000002f559bb10] [d00000000036f338] .__remove_child+0x2c/0x44 [scsi_mod]
[c0000002f559bb90] [c00000000038f11c] .device_for_each_child+0x54/0xb4
[c0000002f559bc50] [d00000000036f2e0] .scsi_remove_target+0x70/0x9c [scsi_mod]
[c0000002f559bce0] [d000000000083454] .fc_starget_delete+0x24/0x3c [scsi_transport_fc]
[c0000002f559bd70] [c0000000000a2368] .run_workqueue+0x118/0x208
[c0000002f559be30] [c0000000000a2580] .worker_thread+0x128/0x154
[c0000002f559bf00] [c0000000000a7470] .kthread+0x78/0xc4
[c0000002f559bf90] [c000000000029b8c] .kernel_thread+0x4c/0x68
Signed-off-by: Brian King <brking@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
|
|
The ibmvfc driver currently logs errors during discovery for several
transient fabric errors, which generally get retried. If retries
do not work, we see multiple errors in the log. If retries do work,
we see errors in the log which may be confusing since the retry worked.
This patch enhances the discovery time error logging to only log errors
for command failures during discovery if all allowed retries have been
used up. The existing behavior of logging all failures can be restored
by setting the hosts log_level to a value of 3 or greater.
Signed-off-by: Brian King <brking@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
|
|
Bump driver version to 1.0.5.
Signed-off-by: Brian King <brking@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
|
|
The ibmvfc driver currently breaks the CRQ and essentially
resets the entire virtual FC adapter, killing all outstanding
ops to all attached targets, if an ADISC times out during target
discover/rediscovery. This patch adds some code to cancel the
ADISC if it times out, which prevents a single ADISC timeout from
affecting the other devices attached to the fabric.
Signed-off-by: Brian King <brking@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
|
|
This patch fixes a problem of possible dropped interrupts. Currently,
the ibmvfc driver has a race condition where after ibmvfc_interrupt
gets run, the platform code clears the interrupt. This can result in
lost interrupts and, in worst case scenarios, result in command
timeouts. Fix this by implementing a tasklet similar to what the
ibmvscsi driver does so that interrupt processing is no longer done in
the actual interrupt handler, which eliminates the race.
Signed-off-by: Brian King <brking@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
|
|
During cancel testing it has been shown that 15 seconds is not
nearly long enough for the VIOS to respond to a cancel under
loaded situations. Increasing this timeout to 60 seconds allows
time for the VIOS to cancel the outstanding commands and prevents
us from escalating to a full host reset, which can take much longer.
Signed-off-by: Brian King <brking@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
|
|
This is a powerpc specific driver.
Signed-off-by: Stephen Rothwell <sfr@canb.auug.org.au>
Signed-off-by: Benjamin Herrenschmidt <benh@kernel.crashing.org>
|
|
While doing various error injection testing, such as cable
pulls and target moves, some issues were observed in handling
these events. This patch improves the way these events are handled
by increasing the delay waiting for the fabric to settle and also
changes the behavior of Link Up to break the CRQ to ensure everything
gets cleaned up properly on the VIOS.
Signed-off-by: Brian King <brking@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
|
|
Adds a delay prior to retrying a failed NPIV login. This fixes
a scenario if the backing fibre channel adapter is getting reset
due to an EEH event, NPIV login will fail. Currently, ibmvfc
retries three times very quickly, resets the CRQ and tries one
more time. If the adapter is getting reset due to EEH, this isn't
enough time. This adds a delay prior to retrying a failed NPIV
login and also increments the number of retries.
Signed-off-by: Brian King <brking@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
|
|
Bump driver version
Signed-off-by: Brian King <brking@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
|
|
The virtual fibre channel stack can return a failure response for a command
indicating the port login has been invalidated without sending the client
an async event. Add code to handle this response and initiate a PLOGI.
Signed-off-by: Brian King <brking@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
|
|
The CRQs used by the ibmvfc driver are read and written by both
the client and the server. Therefore, we need to mark them volatile
so that we do not cache their contents when handling an interrupt.
This fixes a problem which can surface as occasional command timeouts.
No commands were actually timing out, but due to accessing cached data
for the CRQ in the interrupt handler, the interrupt was not processing
all command completions as it should.
Signed-off-by: Brian King <brking@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
|
|
Bump driver version.
Signed-off-by: Brian King <brking@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
|
|
If the ibmvfc driver is in discovery attempting to log into a target
and it encounters an error, the command may get retried one or more
times, depending on the error received. If the retries are
unsuccessful such that the discovery thread gives up on discovery to
that target, the target ends up in a state where, if SCSI core had
previously known about the device, the host will get unblocked but the
host will not be logged into the target, causing any commands sent to
the target to fail. This patch fixes this so that if this occurs, the
target is deleted such that the normal dev_loss processing can occur
instead.
Signed-off-by: Brian King <brking@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
|
|
Due to an ambiguity in the VIOS VFC interface specification,
abort/cancel handling is not done correctly and can result in double
completion of commands. In order to cancel all outstanding commands to
a device, a cancel must be sent, followed by an abort task set. After
the responses are received for these commands, there may still be
commands outstanding, in the process of getting flushed back, in which
case, we need to wait for them. This patch removes the assumption that
if the abort and the cancel both complete successfully that the device
queue has been flushed and waits for all the responses to come back.
Signed-off-by: Brian King <brking@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
|
|
The ibmvfc log level filtering logic was reversed. The log_level scsi
host parameter should result in more verbose logs when log_level is
larger, not smaller.
Signed-off-by: Brian King <brking@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
|
|
Bump driver version to 1.0.2.
Signed-off-by: Brian King <brking@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
|
|
[jejb: fixed up a ton of missed conversions.
All of you are on notice this has happened, driver trees will now
need to be rebased]
Signed-off-by: Harvey Harrison <harvey.harrison@gmail.com>
Cc: SCSI List <linux-scsi@vger.kernel.org>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
|
|
Update driver version to 1.0.1.
Signed-off-by: Brian King <brking@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
|
|
Add an ADISC to the target discovery job in order to sanity check whether or
not we need to re-login to the target.
Signed-off-by: Brian King <brking@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
|
|
This patch adds a new device driver to support the Virtual Fibre Channel
interface on IBM Power based servers. The Virtual I/O Server on IBM Power
servers utilizes N-Port ID Virtualization to export a Virtual Fibre Channel
adapter to the client. This driver is the client device driver.
Signed-off-by: Brian King <brking@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
|