2011-10-03bnx2fc: Fix kernel panic when deleting NPIV portsBhanu Prakash Gollapudi
commit d36b3279e157641c345b12eddb3db78fb42da80f upstream. Deleting NPIV port causes a kernel panic when the NPIV port is in the same zone as the physical port and shares the same LUN. This happens due to the fact that vport destroy and unsolicited ELS are scheduled to run on the same workqueue, and vport destroy destroys the lport and the unsolicited ELS tries to access the invalid lport. This patch fixes this issue by maintaining a list of valid lports and verifying if the lport is valid or not before accessing it. Signed-off-by: Bhanu Prakash Gollapudi <bprakash@broadcom.com> Signed-off-by: James Bottomley <JBottomley@Parallels.com> Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>
2011-05-01[SCSI] bnx2fc: introduce missing kfreeJulia Lawall
Error handling code following a kmalloc should free the allocated data. The semantic match that finds the problem is as follows: (http://www.emn.fr/x-info/coccinelle/) // <smpl> @r exists@ local idexpression x; statement S; expression E; identifier f,f1,l; position p1,p2; expression *ptr != NULL; @@ x@p1 = \(kmalloc\|kzalloc\|kcalloc\)(...); ... if (x == NULL) S <... when != x when != if (...) { <+...x...+> } ( x->f1 = E | (x->f1 == NULL || ...) | f(...,x->f1,...) ) ...> ( return \(0\|<+...x...+>\|ptr\); | return@p2 ...; ) @script:python@ p1 << r.p1; p2 << r.p2; @@ print "* file: %s kmalloc %s return %s" % (p1[0].file,p1[0].line,p2[0].line) // </smpl> Signed-off-by: Julia Lawall <julia@diku.dk> Acked-by: Bhanu Prakash Gollapudi <bprakash@broadcom.com> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
2011-03-23[SCSI] bnx2fc: Fix MTU issue by using static MTUBhanu Gollapudi
bnx2x now uses seperate MTUs for networking and FCoE. FCoE MTU is fixed to 2500 and bnx2fc now needs to match this logic by using FCOE_MTU instead of netdev->mtu. Signed-off-by: Bhanu Prakash Gollapudi <bprakash@broadcom.com> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
2011-03-23[SCSI] bnx2fc: Call bnx2fc_return_rqe and bnx2fc_get_next_rqe with tgt lock heldNithin Sujir
tgt lock is needed during - bnx2fc_return_rqe to protect the rq_prod_idx. bnx2fc_get_next_rqe to protect rq_cons_idx Signed-off-by: Nithin Nayak Sujir <nsujir@broadcom.com> Signed-off-by: Michael Chan <mchan@broadcom.com> Signed-off-by: Bhanu Prakash Gollapudi <bprakash@broadcom.com> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
2011-02-28[SCSI] bnx2fc: Broadcom FCoE offload driverBhanu Gollapudi
This driver is for Broadcom Netxtreme II 57712 chip. The following patch contains the driver sources for bnx2fc driver. libfc/libfcoe changes to enable bnx2fc have already gone through the fcoe tree. bnx2fc is a SCSI low level driver that interfaces with SCSI midlayer, libfc, libfcoe, cnic modules. bnx2fc driver uses services of libfc for slow path operations such as FIP and fabric discovery. The fast path IO perations are performed after offloading the session information to the underlying FCoE firmware. Signed-off-by: Bhanu Prakash Gollapudi <bprakash@broadcom.com> Reviewed-by: Mike Christie <michaelc@cs.wisc.edu> Signed-off-by: James Bottomley <James.Bottomley@suse.de>