diff --git a/Documentation/devicetree/bindings/thermal/exynos-thermal.txt b/Documentation/devicetree/bindings/thermal/exynos-thermal.txt
index 284f5300fd8..c94909215c0 100644
--- a/Documentation/devicetree/bindings/thermal/exynos-thermal.txt
+++ b/Documentation/devicetree/bindings/thermal/exynos-thermal.txt
@@ -6,16 +6,35 @@
"samsung,exynos4412-tmu"
"samsung,exynos4210-tmu"
"samsung,exynos5250-tmu"
+ "samsung,exynos5260-tmu"
+ "samsung,exynos5420-tmu" for TMU channel 0, 1 on Exynos5420
+ "samsung,exynos5420-tmu-ext-triminfo" for TMU channels 2, 3 and 4
+ Exynos5420 (Must pass triminfo base and triminfo clock)
"samsung,exynos5440-tmu"
- interrupt-parent : The phandle for the interrupt controller
- reg : Address range of the thermal registers. For soc's which has multiple
instances of TMU and some registers are shared across all TMU's like
interrupt related then 2 set of register has to supplied. First set
- belongs to each instance of TMU and second set belongs to common TMU
- registers.
+ belongs to register set of TMU instance and second set belongs to
+ registers shared with the TMU instance.
+
+ NOTE: On Exynos5420, the TRIMINFO register is misplaced for TMU
+ channels 2, 3 and 4
+ Use "samsung,exynos5420-tmu-ext-triminfo" in cases, there is a misplaced
+ register, also provide clock to access that base.
+
+ TRIMINFO at 0x1006c000 contains data for TMU channel 3
+ TRIMINFO at 0x100a0000 contains data for TMU channel 4
+ TRIMINFO at 0x10068000 contains data for TMU channel 2
+
- interrupts : Should contain interrupt for thermal system
-- clocks : The main clock for TMU device
+- clocks : The main clocks for TMU device
+ -- 1. operational clock for TMU channel
+ -- 2. optional clock to access the shared registers of TMU channel
- clock-names : Thermal system clock name
+ -- "tmu_apbif" operational clock for current TMU channel
+ -- "tmu_triminfo_apbif" clock to access the shared triminfo register
+ for current TMU channel
- vtmu-supply: This entry is optional and provides the regulator node supplying
voltage to TMU. If needed this entry can be placed inside
board/platform specific dts file.
@@ -43,6 +62,31 @@ Example 2):
clock-names = "tmu_apbif";
};
+Example 3): (In case of Exynos5420 "with misplaced TRIMINFO register")
+ tmu_cpu2: tmu@10068000 {
+ compatible = "samsung,exynos5420-tmu-ext-triminfo";
+ reg = <0x10068000 0x100>, <0x1006c000 0x4>;
+ interrupts = <0 184 0>;
+ clocks = <&clock 318>, <&clock 318>;
+ clock-names = "tmu_apbif", "tmu_triminfo_apbif";
+ };
+
+ tmu_cpu3: tmu@1006c000 {
+ compatible = "samsung,exynos5420-tmu-ext-triminfo";
+ reg = <0x1006c000 0x100>, <0x100a0000 0x4>;
+ interrupts = <0 185 0>;
+ clocks = <&clock 318>, <&clock 319>;
+ clock-names = "tmu_apbif", "tmu_triminfo_apbif";
+ };
+
+ tmu_gpu: tmu@100a0000 {
+ compatible = "samsung,exynos5420-tmu-ext-triminfo";
+ reg = <0x100a0000 0x100>, <0x10068000 0x4>;
+ interrupts = <0 215 0>;
+ clocks = <&clock 319>, <&clock 318>;
+ clock-names = "tmu_apbif", "tmu_triminfo_apbif";
+ };
+
Note: For multi-instance tmu each instance should have an alias correctly
numbered in "aliases" node.