aboutsummaryrefslogtreecommitdiff
diff options
context:
space:
mode:
-rw-r--r--drivers/net/bnx2x/bnx2x.h2
-rw-r--r--drivers/net/bnx2x/bnx2x_cmn.c49
-rw-r--r--drivers/net/bnx2x/bnx2x_cmn.h2
-rw-r--r--drivers/net/bnx2x/bnx2x_ethtool.c34
-rw-r--r--drivers/net/bnx2x/bnx2x_hsi.h12
-rw-r--r--drivers/net/bnx2x/bnx2x_link.c80
-rw-r--r--drivers/net/bnx2x/bnx2x_link.h2
-rw-r--r--drivers/net/bnx2x/bnx2x_main.c39
8 files changed, 162 insertions, 58 deletions
diff --git a/drivers/net/bnx2x/bnx2x.h b/drivers/net/bnx2x/bnx2x.h
index 668a578c49e..480e02df86e 100644
--- a/drivers/net/bnx2x/bnx2x.h
+++ b/drivers/net/bnx2x/bnx2x.h
@@ -1492,7 +1492,7 @@ void bnx2x_invalidate_e1h_mc_list(struct bnx2x *bp);
void bnx2x_invalidate_uc_list(struct bnx2x *bp);
void bnx2x_update_coalesce(struct bnx2x *bp);
-int bnx2x_get_link_cfg_idx(struct bnx2x *bp);
+int bnx2x_get_cur_phy_idx(struct bnx2x *bp);
static inline u32 reg_poll(struct bnx2x *bp, u32 reg, u32 expected, int ms,
int wait)
diff --git a/drivers/net/bnx2x/bnx2x_cmn.c b/drivers/net/bnx2x/bnx2x_cmn.c
index 289044332ed..9b248348c0e 100644
--- a/drivers/net/bnx2x/bnx2x_cmn.c
+++ b/drivers/net/bnx2x/bnx2x_cmn.c
@@ -2803,6 +2803,55 @@ static int bnx2x_reload_if_running(struct net_device *dev)
return bnx2x_nic_load(bp, LOAD_NORMAL);
}
+int bnx2x_get_cur_phy_idx(struct bnx2x *bp)
+{
+ u32 sel_phy_idx = 0;
+ if (bp->link_params.num_phys <= 1)
+ return INT_PHY;
+
+ if (bp->link_vars.link_up) {
+ sel_phy_idx = EXT_PHY1;
+ /* In case link is SERDES, check if the EXT_PHY2 is the one */
+ if ((bp->link_vars.link_status & LINK_STATUS_SERDES_LINK) &&
+ (bp->link_params.phy[EXT_PHY2].supported & SUPPORTED_FIBRE))
+ sel_phy_idx = EXT_PHY2;
+ } else {
+
+ switch (bnx2x_phy_selection(&bp->link_params)) {
+ case PORT_HW_CFG_PHY_SELECTION_HARDWARE_DEFAULT:
+ case PORT_HW_CFG_PHY_SELECTION_FIRST_PHY:
+ case PORT_HW_CFG_PHY_SELECTION_FIRST_PHY_PRIORITY:
+ sel_phy_idx = EXT_PHY1;
+ break;
+ case PORT_HW_CFG_PHY_SELECTION_SECOND_PHY:
+ case PORT_HW_CFG_PHY_SELECTION_SECOND_PHY_PRIORITY:
+ sel_phy_idx = EXT_PHY2;
+ break;
+ }
+ }
+
+ return sel_phy_idx;
+
+}
+int bnx2x_get_link_cfg_idx(struct bnx2x *bp)
+{
+ u32 sel_phy_idx = bnx2x_get_cur_phy_idx(bp);
+ /*
+ * The selected actived PHY is always after swapping (in case PHY
+ * swapping is enabled). So when swapping is enabled, we need to reverse
+ * the configuration
+ */
+
+ if (bp->link_params.multi_phy_config &
+ PORT_HW_CFG_PHY_SWAPPED_ENABLED) {
+ if (sel_phy_idx == EXT_PHY1)
+ sel_phy_idx = EXT_PHY2;
+ else if (sel_phy_idx == EXT_PHY2)
+ sel_phy_idx = EXT_PHY1;
+ }
+ return LINK_CONFIG_IDX(sel_phy_idx);
+}
+
/* called with rtnl_lock */
int bnx2x_change_mtu(struct net_device *dev, int new_mtu)
{
diff --git a/drivers/net/bnx2x/bnx2x_cmn.h b/drivers/net/bnx2x/bnx2x_cmn.h
index 1a3545bd8a9..19f8638ed51 100644
--- a/drivers/net/bnx2x/bnx2x_cmn.h
+++ b/drivers/net/bnx2x/bnx2x_cmn.h
@@ -1063,6 +1063,8 @@ static inline void bnx2x_init_fcoe_fp(struct bnx2x *bp)
}
#endif
+int bnx2x_get_link_cfg_idx(struct bnx2x *bp);
+
static inline void __storm_memset_struct(struct bnx2x *bp,
u32 addr, size_t size, u32 *data)
{
diff --git a/drivers/net/bnx2x/bnx2x_ethtool.c b/drivers/net/bnx2x/bnx2x_ethtool.c
index 727fe89ff37..2957353f7c2 100644
--- a/drivers/net/bnx2x/bnx2x_ethtool.c
+++ b/drivers/net/bnx2x/bnx2x_ethtool.c
@@ -162,6 +162,33 @@ static const struct {
};
#define BNX2X_NUM_STATS ARRAY_SIZE(bnx2x_stats_arr)
+static int bnx2x_get_port_type(struct bnx2x *bp)
+{
+ int port_type;
+ u32 phy_idx = bnx2x_get_cur_phy_idx(bp);
+ switch (bp->link_params.phy[phy_idx].media_type) {
+ case ETH_PHY_SFP_FIBER:
+ case ETH_PHY_XFP_FIBER:
+ case ETH_PHY_KR:
+ case ETH_PHY_CX4:
+ port_type = PORT_FIBRE;
+ break;
+ case ETH_PHY_DA_TWINAX:
+ port_type = PORT_DA;
+ break;
+ case ETH_PHY_BASE_T:
+ port_type = PORT_TP;
+ break;
+ case ETH_PHY_NOT_PRESENT:
+ port_type = PORT_NONE;
+ break;
+ case ETH_PHY_UNSPECIFIED:
+ default:
+ port_type = PORT_OTHER;
+ break;
+ }
+ return port_type;
+}
static int bnx2x_get_settings(struct net_device *dev, struct ethtool_cmd *cmd)
{
@@ -188,12 +215,7 @@ static int bnx2x_get_settings(struct net_device *dev, struct ethtool_cmd *cmd)
if (IS_MF(bp))
ethtool_cmd_speed_set(cmd, bnx2x_get_mf_speed(bp));
- if (bp->port.supported[cfg_idx] & SUPPORTED_TP)
- cmd->port = PORT_TP;
- else if (bp->port.supported[cfg_idx] & SUPPORTED_FIBRE)
- cmd->port = PORT_FIBRE;
- else
- BNX2X_ERR("XGXS PHY Failure detected\n");
+ cmd->port = bnx2x_get_port_type(bp);
cmd->phy_address = bp->mdio.prtad;
cmd->transceiver = XCVR_INTERNAL;
diff --git a/drivers/net/bnx2x/bnx2x_hsi.h b/drivers/net/bnx2x/bnx2x_hsi.h
index 6ee6160ce95..5bfdbcc94a7 100644
--- a/drivers/net/bnx2x/bnx2x_hsi.h
+++ b/drivers/net/bnx2x/bnx2x_hsi.h
@@ -263,7 +263,17 @@ struct port_hw_cfg { /* port 0: 0x12c port 1: 0x2bc */
#define PORT_HW_CFG_FAULT_MODULE_LED_GPIO2 0x00000200
#define PORT_HW_CFG_FAULT_MODULE_LED_GPIO3 0x00000300
#define PORT_HW_CFG_FAULT_MODULE_LED_DISABLED 0x00000400
- u32 Reserved01[12]; /* 0x158 */
+ u32 Reserved01[11]; /* 0x158 */
+
+ u32 media_type; /* 0x194 */
+#define PORT_HW_CFG_MEDIA_TYPE_PHY0_MASK 0x000000FF
+#define PORT_HW_CFG_MEDIA_TYPE_PHY0_SHIFT 0
+
+#define PORT_HW_CFG_MEDIA_TYPE_PHY1_MASK 0x0000FF00
+#define PORT_HW_CFG_MEDIA_TYPE_PHY1_SHIFT 8
+
+#define PORT_HW_CFG_MEDIA_TYPE_PHY2_MASK 0x00FF0000
+#define PORT_HW_CFG_MEDIA_TYPE_PHY2_SHIFT 16
/* for external PHY, or forced mode or during AN */
u16 xgxs_config_rx[4]; /* 0x198 */
diff --git a/drivers/net/bnx2x/bnx2x_link.c b/drivers/net/bnx2x/bnx2x_link.c
index 56b5ed8f634..8a7d7d6b1dd 100644
--- a/drivers/net/bnx2x/bnx2x_link.c
+++ b/drivers/net/bnx2x/bnx2x_link.c
@@ -1618,7 +1618,7 @@ void bnx2x_link_status_update(struct link_params *params,
struct bnx2x *bp = params->bp;
u8 link_10g;
u8 port = params->port;
-
+ u32 sync_offset, media_types;
vars->link_status = REG_RD(bp, params->shmem_base +
offsetof(struct shmem_region,
port_mb[port].link_status));
@@ -1731,6 +1731,23 @@ void bnx2x_link_status_update(struct link_params *params,
vars->mac_type = MAC_TYPE_NONE;
}
+ /* Sync media type */
+ sync_offset = params->shmem_base +
+ offsetof(struct shmem_region,
+ dev_info.port_hw_config[port].media_type);
+ media_types = REG_RD(bp, sync_offset);
+
+ params->phy[INT_PHY].media_type =
+ (media_types & PORT_HW_CFG_MEDIA_TYPE_PHY0_MASK) >>
+ PORT_HW_CFG_MEDIA_TYPE_PHY0_SHIFT;
+ params->phy[EXT_PHY1].media_type =
+ (media_types & PORT_HW_CFG_MEDIA_TYPE_PHY1_MASK) >>
+ PORT_HW_CFG_MEDIA_TYPE_PHY1_SHIFT;
+ params->phy[EXT_PHY2].media_type =
+ (media_types & PORT_HW_CFG_MEDIA_TYPE_PHY2_MASK) >>
+ PORT_HW_CFG_MEDIA_TYPE_PHY2_SHIFT;
+ DP(NETIF_MSG_LINK, "media_types = 0x%x\n", media_types);
+
DP(NETIF_MSG_LINK, "link_status 0x%x phy_link_up %x\n",
vars->link_status, vars->phy_link_up);
DP(NETIF_MSG_LINK, "line_speed %x duplex %x flow_ctrl 0x%x\n",
@@ -3247,7 +3264,9 @@ u8 bnx2x_test_link(struct link_params *params, struct link_vars *vars,
serdes_phy_type = ((params->phy[phy_index].media_type ==
ETH_PHY_SFP_FIBER) ||
(params->phy[phy_index].media_type ==
- ETH_PHY_XFP_FIBER));
+ ETH_PHY_XFP_FIBER) ||
+ (params->phy[phy_index].media_type ==
+ ETH_PHY_DA_TWINAX));
if (is_serdes != serdes_phy_type)
continue;
@@ -4679,9 +4698,11 @@ static u8 bnx2x_get_edc_mode(struct bnx2x_phy *phy,
u16 *edc_mode)
{
struct bnx2x *bp = params->bp;
+ u32 sync_offset = 0, phy_idx, media_types;
u8 val, check_limiting_mode = 0;
*edc_mode = EDC_MODE_LIMITING;
+ phy->media_type = ETH_PHY_UNSPECIFIED;
/* First check for copper cable */
if (bnx2x_read_sfp_module_eeprom(phy,
params,
@@ -4696,7 +4717,7 @@ static u8 bnx2x_get_edc_mode(struct bnx2x_phy *phy,
case SFP_EEPROM_CON_TYPE_VAL_COPPER:
{
u8 copper_module_type;
-
+ phy->media_type = ETH_PHY_DA_TWINAX;
/*
* Check if its active cable (includes SFP+ module)
* of passive cable
@@ -4731,6 +4752,7 @@ static u8 bnx2x_get_edc_mode(struct bnx2x_phy *phy,
break;
}
case SFP_EEPROM_CON_TYPE_VAL_LC:
+ phy->media_type = ETH_PHY_SFP_FIBER;
DP(NETIF_MSG_LINK, "Optic module detected\n");
check_limiting_mode = 1;
break;
@@ -4739,7 +4761,22 @@ static u8 bnx2x_get_edc_mode(struct bnx2x_phy *phy,
val);
return -EINVAL;
}
-
+ sync_offset = params->shmem_base +
+ offsetof(struct shmem_region,
+ dev_info.port_hw_config[params->port].media_type);
+ media_types = REG_RD(bp, sync_offset);
+ /* Update media type for non-PMF sync */
+ for (phy_idx = INT_PHY; phy_idx < MAX_PHYS; phy_idx++) {
+ if (&(params->phy[phy_idx]) == phy) {
+ media_types &= ~(PORT_HW_CFG_MEDIA_TYPE_PHY0_MASK <<
+ (PORT_HW_CFG_MEDIA_TYPE_PHY1_SHIFT * phy_idx));
+ media_types |= ((phy->media_type &
+ PORT_HW_CFG_MEDIA_TYPE_PHY0_MASK) <<
+ (PORT_HW_CFG_MEDIA_TYPE_PHY1_SHIFT * phy_idx));
+ break;
+ }
+ }
+ REG_WR(bp, sync_offset, media_types);
if (check_limiting_mode) {
u8 options[SFP_EEPROM_OPTIONS_SIZE];
if (bnx2x_read_sfp_module_eeprom(phy,
@@ -5156,6 +5193,7 @@ void bnx2x_handle_module_detect_int(struct link_params *params)
* Module was plugged out.
* Disable transmit for this module
*/
+ phy->media_type = ETH_PHY_NOT_PRESENT;
if ((val & PORT_FEAT_CFG_OPT_MDL_ENFRCMNT_MASK) ==
PORT_FEAT_CFG_OPT_MDL_ENFRCMNT_DISABLE_TX_LASER)
bnx2x_sfp_set_transmitter(params, phy, 0);
@@ -5764,7 +5802,7 @@ static void bnx2x_8727_handle_mod_abs(struct bnx2x_phy *phy,
/* Module is absent */
DP(NETIF_MSG_LINK, "MOD_ABS indication "
"show module is absent\n");
-
+ phy->media_type = ETH_PHY_NOT_PRESENT;
/*
* 1. Set mod_abs to detect next module
* presence event
@@ -6877,7 +6915,7 @@ static struct bnx2x_phy phy_serdes = {
SUPPORTED_Autoneg |
SUPPORTED_Pause |
SUPPORTED_Asym_Pause),
- .media_type = ETH_PHY_UNSPECIFIED,
+ .media_type = ETH_PHY_BASE_T,
.ver_addr = 0,
.req_flow_ctrl = 0,
.req_line_speed = 0,
@@ -6914,7 +6952,7 @@ static struct bnx2x_phy phy_xgxs = {
SUPPORTED_Autoneg |
SUPPORTED_Pause |
SUPPORTED_Asym_Pause),
- .media_type = ETH_PHY_UNSPECIFIED,
+ .media_type = ETH_PHY_CX4,
.ver_addr = 0,
.req_flow_ctrl = 0,
.req_line_speed = 0,
@@ -6977,7 +7015,7 @@ static struct bnx2x_phy phy_8073 = {
SUPPORTED_Autoneg |
SUPPORTED_Pause |
SUPPORTED_Asym_Pause),
- .media_type = ETH_PHY_UNSPECIFIED,
+ .media_type = ETH_PHY_KR,
.ver_addr = 0,
.req_flow_ctrl = 0,
.req_line_speed = 0,
@@ -7069,7 +7107,7 @@ static struct bnx2x_phy phy_8726 = {
SUPPORTED_FIBRE |
SUPPORTED_Pause |
SUPPORTED_Asym_Pause),
- .media_type = ETH_PHY_SFP_FIBER,
+ .media_type = ETH_PHY_NOT_PRESENT,
.ver_addr = 0,
.req_flow_ctrl = 0,
.req_line_speed = 0,
@@ -7100,7 +7138,7 @@ static struct bnx2x_phy phy_8727 = {
SUPPORTED_FIBRE |
SUPPORTED_Pause |
SUPPORTED_Asym_Pause),
- .media_type = ETH_PHY_SFP_FIBER,
+ .media_type = ETH_PHY_NOT_PRESENT,
.ver_addr = 0,
.req_flow_ctrl = 0,
.req_line_speed = 0,
@@ -7565,7 +7603,7 @@ u32 bnx2x_phy_selection(struct link_params *params)
u8 bnx2x_phy_probe(struct link_params *params)
{
u8 phy_index, actual_phy_idx, link_cfg_idx;
- u32 phy_config_swapped;
+ u32 phy_config_swapped, sync_offset, media_types;
struct bnx2x *bp = params->bp;
struct bnx2x_phy *phy;
params->num_phys = 0;
@@ -7602,6 +7640,26 @@ u8 bnx2x_phy_probe(struct link_params *params)
if (phy->type == PORT_HW_CFG_XGXS_EXT_PHY_TYPE_NOT_CONN)
break;
+ sync_offset = params->shmem_base +
+ offsetof(struct shmem_region,
+ dev_info.port_hw_config[params->port].media_type);
+ media_types = REG_RD(bp, sync_offset);
+
+ /*
+ * Update media type for non-PMF sync only for the first time
+ * In case the media type changes afterwards, it will be updated
+ * using the update_status function
+ */
+ if ((media_types & (PORT_HW_CFG_MEDIA_TYPE_PHY0_MASK <<
+ (PORT_HW_CFG_MEDIA_TYPE_PHY1_SHIFT *
+ actual_phy_idx))) == 0) {
+ media_types |= ((phy->media_type &
+ PORT_HW_CFG_MEDIA_TYPE_PHY0_MASK) <<
+ (PORT_HW_CFG_MEDIA_TYPE_PHY1_SHIFT *
+ actual_phy_idx));
+ }
+ REG_WR(bp, sync_offset, media_types);
+
bnx2x_phy_def_cfg(params, phy, phy_index);
params->num_phys++;
}
diff --git a/drivers/net/bnx2x/bnx2x_link.h b/drivers/net/bnx2x/bnx2x_link.h
index 92f36b6950d..ac348daae2f 100644
--- a/drivers/net/bnx2x/bnx2x_link.h
+++ b/drivers/net/bnx2x/bnx2x_link.h
@@ -153,6 +153,8 @@ struct bnx2x_phy {
#define ETH_PHY_XFP_FIBER 0x2
#define ETH_PHY_DA_TWINAX 0x3
#define ETH_PHY_BASE_T 0x4
+#define ETH_PHY_KR 0xf0
+#define ETH_PHY_CX4 0xf1
#define ETH_PHY_NOT_PRESENT 0xff
/* The address in which version is located*/
diff --git a/drivers/net/bnx2x/bnx2x_main.c b/drivers/net/bnx2x/bnx2x_main.c
index 4b70311a11e..c6591c46ebd 100644
--- a/drivers/net/bnx2x/bnx2x_main.c
+++ b/drivers/net/bnx2x/bnx2x_main.c
@@ -1732,45 +1732,6 @@ static int bnx2x_set_spio(struct bnx2x *bp, int spio_num, u32 mode)
return 0;
}
-int bnx2x_get_link_cfg_idx(struct bnx2x *bp)
-{
- u32 sel_phy_idx = 0;
- if (bp->link_vars.link_up) {
- sel_phy_idx = EXT_PHY1;
- /* In case link is SERDES, check if the EXT_PHY2 is the one */
- if ((bp->link_vars.link_status & LINK_STATUS_SERDES_LINK) &&
- (bp->link_params.phy[EXT_PHY2].supported & SUPPORTED_FIBRE))
- sel_phy_idx = EXT_PHY2;
- } else {
-
- switch (bnx2x_phy_selection(&bp->link_params)) {
- case PORT_HW_CFG_PHY_SELECTION_HARDWARE_DEFAULT:
- case PORT_HW_CFG_PHY_SELECTION_FIRST_PHY:
- case PORT_HW_CFG_PHY_SELECTION_FIRST_PHY_PRIORITY:
- sel_phy_idx = EXT_PHY1;
- break;
- case PORT_HW_CFG_PHY_SELECTION_SECOND_PHY:
- case PORT_HW_CFG_PHY_SELECTION_SECOND_PHY_PRIORITY:
- sel_phy_idx = EXT_PHY2;
- break;
- }
- }
- /*
- * The selected actived PHY is always after swapping (in case PHY
- * swapping is enabled). So when swapping is enabled, we need to reverse
- * the configuration
- */
-
- if (bp->link_params.multi_phy_config &
- PORT_HW_CFG_PHY_SWAPPED_ENABLED) {
- if (sel_phy_idx == EXT_PHY1)
- sel_phy_idx = EXT_PHY2;
- else if (sel_phy_idx == EXT_PHY2)
- sel_phy_idx = EXT_PHY1;
- }
- return LINK_CONFIG_IDX(sel_phy_idx);
-}
-
void bnx2x_calc_fc_adv(struct bnx2x *bp)
{
u8 cfg_idx = bnx2x_get_link_cfg_idx(bp);