aboutsummaryrefslogtreecommitdiff
path: root/drivers/usb/serial/ftdi_sio.c
diff options
context:
space:
mode:
authorMarko Hänninen <bugitus@gmail.com>2009-07-31 22:32:39 +0300
committerGreg Kroah-Hartman <gregkh@suse.de>2009-08-07 16:05:13 -0700
commitc47aacc67a3d26dfab9c9b8965975ed2b2010b30 (patch)
tree99e69c7e03b60a1ec074f3a6b5ad6fe70a48a79c /drivers/usb/serial/ftdi_sio.c
parentef4638f955f2c4a667c8af20769d03f5ed3781ca (diff)
USB: ftdi_sio: add vendor and product id for Bayer glucose meter serial converter cable
Attached patch adds USB vendor and product IDs for Bayer's USB to serial converter cable used by Bayer blood glucose meters. It seems to be a FT232RL based device and works without any problem with ftdi_sio driver when this patch is applied. See: http://winglucofacts.com/cables/ Signed-off-by: Marko Hänninen <bugitus@gmail.com> Cc: stable <stable@kernel.org> Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>
Diffstat (limited to 'drivers/usb/serial/ftdi_sio.c')
-rw-r--r--drivers/usb/serial/ftdi_sio.c1
1 files changed, 1 insertions, 0 deletions
diff --git a/drivers/usb/serial/ftdi_sio.c b/drivers/usb/serial/ftdi_sio.c
index b574878c78b..500087ea58a 100644
--- a/drivers/usb/serial/ftdi_sio.c
+++ b/drivers/usb/serial/ftdi_sio.c
@@ -699,6 +699,7 @@ static struct usb_device_id id_table_combined [] = {
.driver_info = (kernel_ulong_t)&ftdi_jtag_quirk },
{ USB_DEVICE(LARSENBRUSGAARD_VID, LB_ALTITRACK_PID) },
{ USB_DEVICE(GN_OTOMETRICS_VID, AURICAL_USB_PID) },
+ { USB_DEVICE(BAYER_VID, BAYER_CONTOUR_CABLE_PID) },
{ }, /* Optional parameter entry */
{ } /* Terminating entry */
};