aboutsummaryrefslogtreecommitdiff
path: root/drivers/net/igb/e1000_phy.c
diff options
context:
space:
mode:
authorJoseph Gasparakis <joseph.gasparakis@intel.com>2010-09-22 17:56:44 +0000
committerDavid S. Miller <davem@davemloft.net>2010-09-22 21:20:04 -0700
commit308fb39a860c816be8741fe783ae7c64e9c1af5d (patch)
tree8fabed4b3372c49b4d83dc1d0b72d4abf60f139e /drivers/net/igb/e1000_phy.c
parentd85b9004bc2047d79248b167cc151ff9a4b509c3 (diff)
igb: Add support for DH89xxCC
This patch adds support for the Intel(r) DH89xxCC series. The new device will be using Intel(r) i347-AT4 and Marvell(r) M88E1322 and M88E1112 PHYs. Support for these devices has also been added here. Signed-off-by: Joseph Gasparakis <joseph.gasparakis@intel.com> Tested-by: Jeff Pieper <jeffrey.e.pieper@intel.com> Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com> Signed-off-by: David S. Miller <davem@davemloft.net>
Diffstat (limited to 'drivers/net/igb/e1000_phy.c')
-rw-r--r--drivers/net/igb/e1000_phy.c206
1 files changed, 194 insertions, 12 deletions
diff --git a/drivers/net/igb/e1000_phy.c b/drivers/net/igb/e1000_phy.c
index cf1f3230092..ddd036a7899 100644
--- a/drivers/net/igb/e1000_phy.c
+++ b/drivers/net/igb/e1000_phy.c
@@ -570,6 +570,89 @@ out:
}
/**
+ * igb_copper_link_setup_m88_gen2 - Setup m88 PHY's for copper link
+ * @hw: pointer to the HW structure
+ *
+ * Sets up MDI/MDI-X and polarity for i347-AT4, m88e1322 and m88e1112 PHY's.
+ * Also enables and sets the downshift parameters.
+ **/
+s32 igb_copper_link_setup_m88_gen2(struct e1000_hw *hw)
+{
+ struct e1000_phy_info *phy = &hw->phy;
+ s32 ret_val;
+ u16 phy_data;
+
+ if (phy->reset_disable) {
+ ret_val = 0;
+ goto out;
+ }
+
+ /* Enable CRS on Tx. This must be set for half-duplex operation. */
+ ret_val = phy->ops.read_reg(hw, M88E1000_PHY_SPEC_CTRL, &phy_data);
+ if (ret_val)
+ goto out;
+
+ /*
+ * Options:
+ * MDI/MDI-X = 0 (default)
+ * 0 - Auto for all speeds
+ * 1 - MDI mode
+ * 2 - MDI-X mode
+ * 3 - Auto for 1000Base-T only (MDI-X for 10/100Base-T modes)
+ */
+ phy_data &= ~M88E1000_PSCR_AUTO_X_MODE;
+
+ switch (phy->mdix) {
+ case 1:
+ phy_data |= M88E1000_PSCR_MDI_MANUAL_MODE;
+ break;
+ case 2:
+ phy_data |= M88E1000_PSCR_MDIX_MANUAL_MODE;
+ break;
+ case 3:
+ /* M88E1112 does not support this mode) */
+ if (phy->id != M88E1112_E_PHY_ID) {
+ phy_data |= M88E1000_PSCR_AUTO_X_1000T;
+ break;
+ }
+ case 0:
+ default:
+ phy_data |= M88E1000_PSCR_AUTO_X_MODE;
+ break;
+ }
+
+ /*
+ * Options:
+ * disable_polarity_correction = 0 (default)
+ * Automatic Correction for Reversed Cable Polarity
+ * 0 - Disabled
+ * 1 - Enabled
+ */
+ phy_data &= ~M88E1000_PSCR_POLARITY_REVERSAL;
+ if (phy->disable_polarity_correction == 1)
+ phy_data |= M88E1000_PSCR_POLARITY_REVERSAL;
+
+ /* Enable downshift and setting it to X6 */
+ phy_data &= ~I347AT4_PSCR_DOWNSHIFT_MASK;
+ phy_data |= I347AT4_PSCR_DOWNSHIFT_6X;
+ phy_data |= I347AT4_PSCR_DOWNSHIFT_ENABLE;
+
+ ret_val = phy->ops.write_reg(hw, M88E1000_PHY_SPEC_CTRL, phy_data);
+ if (ret_val)
+ goto out;
+
+ /* Commit the changes. */
+ ret_val = igb_phy_sw_reset(hw);
+ if (ret_val) {
+ hw_dbg("Error committing the PHY changes\n");
+ goto out;
+ }
+
+out:
+ return ret_val;
+}
+
+/**
* igb_copper_link_setup_igp - Setup igp PHY's for copper link
* @hw: pointer to the HW structure
*
@@ -1124,18 +1207,25 @@ s32 igb_phy_force_speed_duplex_m88(struct e1000_hw *hw)
goto out;
if (!link) {
- /*
- * We didn't get link.
- * Reset the DSP and cross our fingers.
- */
- ret_val = phy->ops.write_reg(hw,
- M88E1000_PHY_PAGE_SELECT,
- 0x001d);
- if (ret_val)
- goto out;
- ret_val = igb_phy_reset_dsp(hw);
- if (ret_val)
- goto out;
+ if (hw->phy.type != e1000_phy_m88 ||
+ hw->phy.id == I347AT4_E_PHY_ID ||
+ hw->phy.id == M88E1112_E_PHY_ID) {
+ hw_dbg("Link taking longer than expected.\n");
+ } else {
+
+ /*
+ * We didn't get link.
+ * Reset the DSP and cross our fingers.
+ */
+ ret_val = phy->ops.write_reg(hw,
+ M88E1000_PHY_PAGE_SELECT,
+ 0x001d);
+ if (ret_val)
+ goto out;
+ ret_val = igb_phy_reset_dsp(hw);
+ if (ret_val)
+ goto out;
+ }
}
/* Try once more */
@@ -1145,6 +1235,11 @@ s32 igb_phy_force_speed_duplex_m88(struct e1000_hw *hw)
goto out;
}
+ if (hw->phy.type != e1000_phy_m88 ||
+ hw->phy.id == I347AT4_E_PHY_ID ||
+ hw->phy.id == M88E1112_E_PHY_ID)
+ goto out;
+
ret_val = phy->ops.read_reg(hw, M88E1000_EXT_PHY_SPEC_CTRL, &phy_data);
if (ret_val)
goto out;
@@ -1557,6 +1652,93 @@ out:
return ret_val;
}
+s32 igb_get_cable_length_m88_gen2(struct e1000_hw *hw)
+{
+ struct e1000_phy_info *phy = &hw->phy;
+ s32 ret_val;
+ u16 phy_data, phy_data2, index, default_page, is_cm;
+
+ switch (hw->phy.id) {
+ case I347AT4_E_PHY_ID:
+ /* Remember the original page select and set it to 7 */
+ ret_val = phy->ops.read_reg(hw, I347AT4_PAGE_SELECT,
+ &default_page);
+ if (ret_val)
+ goto out;
+
+ ret_val = phy->ops.write_reg(hw, I347AT4_PAGE_SELECT, 0x07);
+ if (ret_val)
+ goto out;
+
+ /* Get cable length from PHY Cable Diagnostics Control Reg */
+ ret_val = phy->ops.read_reg(hw, (I347AT4_PCDL + phy->addr),
+ &phy_data);
+ if (ret_val)
+ goto out;
+
+ /* Check if the unit of cable length is meters or cm */
+ ret_val = phy->ops.read_reg(hw, I347AT4_PCDC, &phy_data2);
+ if (ret_val)
+ goto out;
+
+ is_cm = !(phy_data & I347AT4_PCDC_CABLE_LENGTH_UNIT);
+
+ /* Populate the phy structure with cable length in meters */
+ phy->min_cable_length = phy_data / (is_cm ? 100 : 1);
+ phy->max_cable_length = phy_data / (is_cm ? 100 : 1);
+ phy->cable_length = phy_data / (is_cm ? 100 : 1);
+
+ /* Reset the page selec to its original value */
+ ret_val = phy->ops.write_reg(hw, I347AT4_PAGE_SELECT,
+ default_page);
+ if (ret_val)
+ goto out;
+ break;
+ case M88E1112_E_PHY_ID:
+ /* Remember the original page select and set it to 5 */
+ ret_val = phy->ops.read_reg(hw, I347AT4_PAGE_SELECT,
+ &default_page);
+ if (ret_val)
+ goto out;
+
+ ret_val = phy->ops.write_reg(hw, I347AT4_PAGE_SELECT, 0x05);
+ if (ret_val)
+ goto out;
+
+ ret_val = phy->ops.read_reg(hw, M88E1112_VCT_DSP_DISTANCE,
+ &phy_data);
+ if (ret_val)
+ goto out;
+
+ index = (phy_data & M88E1000_PSSR_CABLE_LENGTH) >>
+ M88E1000_PSSR_CABLE_LENGTH_SHIFT;
+ if (index >= M88E1000_CABLE_LENGTH_TABLE_SIZE - 1) {
+ ret_val = -E1000_ERR_PHY;
+ goto out;
+ }
+
+ phy->min_cable_length = e1000_m88_cable_length_table[index];
+ phy->max_cable_length = e1000_m88_cable_length_table[index + 1];
+
+ phy->cable_length = (phy->min_cable_length +
+ phy->max_cable_length) / 2;
+
+ /* Reset the page select to its original value */
+ ret_val = phy->ops.write_reg(hw, I347AT4_PAGE_SELECT,
+ default_page);
+ if (ret_val)
+ goto out;
+
+ break;
+ default:
+ ret_val = -E1000_ERR_PHY;
+ goto out;
+ }
+
+out:
+ return ret_val;
+}
+
/**
* igb_get_cable_length_igp_2 - Determine cable length for igp2 PHY
* @hw: pointer to the HW structure