aboutsummaryrefslogtreecommitdiff
path: root/drivers/block
diff options
context:
space:
mode:
authorMichael S. Tsirkin <mst@redhat.com>2012-01-12 15:44:44 +1030
committerRusty Russell <rusty@rustcorp.com.au>2012-01-12 15:44:44 +1030
commit4678d6f970c2f7c0cbfefc0cc666432d153b321b (patch)
tree6757c596f991c36b38e4d6bb29df4ad0f49c330d /drivers/block
parente93300b1afc7cd4fe1e741ceaf06714d060e88b8 (diff)
virtio_blk: fix config handler race
Fix a theoretical race related to config work handler: a config interrupt might happen after we flush config work but before we reset the device. It will then cause the config work to run during or after reset. Two problems with this: - if this runs after device is gone we will get use after free - access of config while reset is in progress is racy (as layout is changing). As a solution 1. flush after reset when we know there will be no more interrupts 2. add a flag to disable config access before reset Signed-off-by: Michael S. Tsirkin <mst@redhat.com> Signed-off-by: Rusty Russell <rusty@rustcorp.com.au>
Diffstat (limited to 'drivers/block')
-rw-r--r--drivers/block/virtio_blk.c22
1 files changed, 21 insertions, 1 deletions
diff --git a/drivers/block/virtio_blk.c b/drivers/block/virtio_blk.c
index a345e40e1bc..ba73661fb9f 100644
--- a/drivers/block/virtio_blk.c
+++ b/drivers/block/virtio_blk.c
@@ -4,6 +4,7 @@
#include <linux/blkdev.h>
#include <linux/hdreg.h>
#include <linux/module.h>
+#include <linux/mutex.h>
#include <linux/virtio.h>
#include <linux/virtio_blk.h>
#include <linux/scatterlist.h>
@@ -36,6 +37,12 @@ struct virtio_blk
/* Process context for config space updates */
struct work_struct config_work;
+ /* Lock for config space updates */
+ struct mutex config_lock;
+
+ /* enable config space updates */
+ bool config_enable;
+
/* What host tells us, plus 2 for header & tailer. */
unsigned int sg_elems;
@@ -318,6 +325,10 @@ static void virtblk_config_changed_work(struct work_struct *work)
char cap_str_2[10], cap_str_10[10];
u64 capacity, size;
+ mutex_lock(&vblk->config_lock);
+ if (!vblk->config_enable)
+ goto done;
+
/* Host must always specify the capacity. */
vdev->config->get(vdev, offsetof(struct virtio_blk_config, capacity),
&capacity, sizeof(capacity));
@@ -340,6 +351,8 @@ static void virtblk_config_changed_work(struct work_struct *work)
cap_str_10, cap_str_2);
set_capacity(vblk->disk, capacity);
+done:
+ mutex_unlock(&vblk->config_lock);
}
static void virtblk_config_changed(struct virtio_device *vdev)
@@ -388,7 +401,9 @@ static int __devinit virtblk_probe(struct virtio_device *vdev)
vblk->vdev = vdev;
vblk->sg_elems = sg_elems;
sg_init_table(vblk->sg, vblk->sg_elems);
+ mutex_init(&vblk->config_lock);
INIT_WORK(&vblk->config_work, virtblk_config_changed_work);
+ vblk->config_enable = true;
/* We expect one virtqueue, for output. */
vblk->vq = virtio_find_single_vq(vdev, blk_done, "requests");
@@ -542,7 +557,10 @@ static void __devexit virtblk_remove(struct virtio_device *vdev)
struct virtio_blk *vblk = vdev->priv;
int index = vblk->index;
- flush_work(&vblk->config_work);
+ /* Prevent config work handler from accessing the device. */
+ mutex_lock(&vblk->config_lock);
+ vblk->config_enable = false;
+ mutex_unlock(&vblk->config_lock);
/* Nothing should be pending. */
BUG_ON(!list_empty(&vblk->reqs));
@@ -550,6 +568,8 @@ static void __devexit virtblk_remove(struct virtio_device *vdev)
/* Stop all the virtqueues. */
vdev->config->reset(vdev);
+ flush_work(&vblk->config_work);
+
del_gendisk(vblk->disk);
blk_cleanup_queue(vblk->disk->queue);
put_disk(vblk->disk);