aboutsummaryrefslogtreecommitdiff
path: root/arch/powerpc/platforms
diff options
context:
space:
mode:
authorBenjamin Herrenschmidt <benh@kernel.crashing.org>2012-07-31 15:18:31 +1000
committerBenjamin Herrenschmidt <benh@kernel.crashing.org>2012-07-31 15:18:31 +1000
commitb6965f7967a64b185d7ff4cc4bcf15c380c1348f (patch)
treee8d8b25b54288b3b5ffbdf40c59c637abee4a86b /arch/powerpc/platforms
parent1fad1e9a747687a7399bf58e87974f9b1bbcae06 (diff)
parent896c01cb4bb3cfc2c0ea9873fa7a9f8bd0a7c8d8 (diff)
Merge remote-tracking branch 'kumar/merge' into merge
Kumar says: "A few patches that missed the initial 3.6 window. These are bug fixes at this point."
Diffstat (limited to 'arch/powerpc/platforms')
-rw-r--r--arch/powerpc/platforms/85xx/p1022_ds.c122
1 files changed, 100 insertions, 22 deletions
diff --git a/arch/powerpc/platforms/85xx/p1022_ds.c b/arch/powerpc/platforms/85xx/p1022_ds.c
index 89ee02c5456..3c732acf331 100644
--- a/arch/powerpc/platforms/85xx/p1022_ds.c
+++ b/arch/powerpc/platforms/85xx/p1022_ds.c
@@ -208,6 +208,7 @@ static void p1022ds_set_monitor_port(enum fsl_diu_monitor_port port)
u8 __iomem *lbc_lcs0_ba = NULL;
u8 __iomem *lbc_lcs1_ba = NULL;
phys_addr_t cs0_addr, cs1_addr;
+ u32 br0, or0, br1, or1;
const __be32 *iprop;
unsigned int num_laws;
u8 b;
@@ -256,11 +257,70 @@ static void p1022ds_set_monitor_port(enum fsl_diu_monitor_port port)
}
num_laws = be32_to_cpup(iprop);
- cs0_addr = lbc_br_to_phys(ecm, num_laws, in_be32(&lbc->bank[0].br));
- cs1_addr = lbc_br_to_phys(ecm, num_laws, in_be32(&lbc->bank[1].br));
+ /*
+ * Indirect mode requires both BR0 and BR1 to be set to "GPCM",
+ * otherwise writes to these addresses won't actually appear on the
+ * local bus, and so the PIXIS won't see them.
+ *
+ * In FCM mode, writes go to the NAND controller, which does not pass
+ * them to the localbus directly. So we force BR0 and BR1 into GPCM
+ * mode, since we don't care about what's behind the localbus any
+ * more.
+ */
+ br0 = in_be32(&lbc->bank[0].br);
+ br1 = in_be32(&lbc->bank[1].br);
+ or0 = in_be32(&lbc->bank[0].or);
+ or1 = in_be32(&lbc->bank[1].or);
+
+ /* Make sure CS0 and CS1 are programmed */
+ if (!(br0 & BR_V) || !(br1 & BR_V)) {
+ pr_err("p1022ds: CS0 and/or CS1 is not programmed\n");
+ goto exit;
+ }
+
+ /*
+ * Use the existing BRx/ORx values if it's already GPCM. Otherwise,
+ * force the values to simple 32KB GPCM windows with the most
+ * conservative timing.
+ */
+ if ((br0 & BR_MSEL) != BR_MS_GPCM) {
+ br0 = (br0 & BR_BA) | BR_V;
+ or0 = 0xFFFF8000 | 0xFF7;
+ out_be32(&lbc->bank[0].br, br0);
+ out_be32(&lbc->bank[0].or, or0);
+ }
+ if ((br1 & BR_MSEL) != BR_MS_GPCM) {
+ br1 = (br1 & BR_BA) | BR_V;
+ or1 = 0xFFFF8000 | 0xFF7;
+ out_be32(&lbc->bank[1].br, br1);
+ out_be32(&lbc->bank[1].or, or1);
+ }
+
+ cs0_addr = lbc_br_to_phys(ecm, num_laws, br0);
+ if (!cs0_addr) {
+ pr_err("p1022ds: could not determine physical address for CS0"
+ " (BR0=%08x)\n", br0);
+ goto exit;
+ }
+ cs1_addr = lbc_br_to_phys(ecm, num_laws, br1);
+ if (!cs0_addr) {
+ pr_err("p1022ds: could not determine physical address for CS1"
+ " (BR1=%08x)\n", br1);
+ goto exit;
+ }
lbc_lcs0_ba = ioremap(cs0_addr, 1);
+ if (!lbc_lcs0_ba) {
+ pr_err("p1022ds: could not ioremap CS0 address %llx\n",
+ (unsigned long long)cs0_addr);
+ goto exit;
+ }
lbc_lcs1_ba = ioremap(cs1_addr, 1);
+ if (!lbc_lcs1_ba) {
+ pr_err("p1022ds: could not ioremap CS1 address %llx\n",
+ (unsigned long long)cs1_addr);
+ goto exit;
+ }
/* Make sure we're in indirect mode first. */
if ((in_be32(&guts->pmuxcr) & PMUXCR_ELBCDIU_MASK) !=
@@ -419,18 +479,6 @@ void __init p1022_ds_pic_init(void)
#if defined(CONFIG_FB_FSL_DIU) || defined(CONFIG_FB_FSL_DIU_MODULE)
-/*
- * Disables a node in the device tree.
- *
- * This function is called before kmalloc() is available, so the 'new' object
- * should be allocated in the global area. The easiest way is to do that is
- * to allocate one static local variable for each call to this function.
- */
-static void __init disable_one_node(struct device_node *np, struct property *new)
-{
- prom_update_property(np, new);
-}
-
/* TRUE if there is a "video=fslfb" command-line parameter. */
static bool fslfb;
@@ -493,28 +541,58 @@ static void __init p1022_ds_setup_arch(void)
diu_ops.valid_monitor_port = p1022ds_valid_monitor_port;
/*
- * Disable the NOR flash node if there is video=fslfb... command-line
- * parameter. When the DIU is active, NOR flash is unavailable, so we
- * have to disable the node before the MTD driver loads.
+ * Disable the NOR and NAND flash nodes if there is video=fslfb...
+ * command-line parameter. When the DIU is active, the localbus is
+ * unavailable, so we have to disable these nodes before the MTD
+ * driver loads.
*/
if (fslfb) {
struct device_node *np =
of_find_compatible_node(NULL, NULL, "fsl,p1022-elbc");
if (np) {
- np = of_find_compatible_node(np, NULL, "cfi-flash");
- if (np) {
+ struct device_node *np2;
+
+ of_node_get(np);
+ np2 = of_find_compatible_node(np, NULL, "cfi-flash");
+ if (np2) {
static struct property nor_status = {
.name = "status",
.value = "disabled",
.length = sizeof("disabled"),
};
+ /*
+ * prom_update_property() is called before
+ * kmalloc() is available, so the 'new' object
+ * should be allocated in the global area.
+ * The easiest way is to do that is to
+ * allocate one static local variable for each
+ * call to this function.
+ */
pr_info("p1022ds: disabling %s node",
- np->full_name);
- disable_one_node(np, &nor_status);
- of_node_put(np);
+ np2->full_name);
+ prom_update_property(np2, &nor_status);
+ of_node_put(np2);
}
+
+ of_node_get(np);
+ np2 = of_find_compatible_node(np, NULL,
+ "fsl,elbc-fcm-nand");
+ if (np2) {
+ static struct property nand_status = {
+ .name = "status",
+ .value = "disabled",
+ .length = sizeof("disabled"),
+ };
+
+ pr_info("p1022ds: disabling %s node",
+ np2->full_name);
+ prom_update_property(np2, &nand_status);
+ of_node_put(np2);
+ }
+
+ of_node_put(np);
}
}