diff options
author | Guenter Roeck <guenter.roeck@ericsson.com> | 2011-04-29 16:33:35 +0200 |
---|---|---|
committer | Jean Delvare <khali@endymion.delvare> | 2011-04-29 16:33:35 +0200 |
commit | 177e75925bead0c1f8bb8b2e69bcddabb1e07c11 (patch) | |
tree | d25eef425bcba6e054381dedff58bc811884bcc9 | |
parent | 5a4e5e6a701bea7d3cbeed19fa9ea45802e8fabb (diff) |
hwmon: (lm90) Fix update interval information in driver documentation
The lm90 driver's attribute update interval is configurable.
Reflect this information in the driver documentation.
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Signed-off-by: Jean Delvare <khali@linux-fr.org>
-rw-r--r-- | Documentation/hwmon/lm90 | 6 |
1 files changed, 3 insertions, 3 deletions
diff --git a/Documentation/hwmon/lm90 b/Documentation/hwmon/lm90 index aa820aca795..f3efd18e87f 100644 --- a/Documentation/hwmon/lm90 +++ b/Documentation/hwmon/lm90 @@ -205,9 +205,9 @@ are exported, one for each channel, but these values are of course linked. Only the local hysteresis can be set from user-space, and the same delta applies to the remote hysteresis. -The lm90 driver will not update its values more frequently than every -other second; reading them more often will do no harm, but will return -'old' values. +The lm90 driver will not update its values more frequently than configured with +the update_interval attribute; reading them more often will do no harm, but will +return 'old' values. SMBus Alert Support ------------------- |