authorMark Brown <broonie@opensource.wolfsonmicro.com>2009-04-09 19:00:19 +0100
committerBen Dooks <ben-linux@fluff.org>2009-05-01 11:38:46 +0100
commitdb9256f33c1b9ce72d2a126d51c7fe0de65f0f8c (patch)
treeeb74922396ffc874451a6aff67560b21bc4f381d
parent87c4122f1714f96faa1b1c9449f762b9c56f77e4 (diff)
[ARM] SMDK6410: Use active high IRQ for the WM8350 on the WM1190-EV1
Using an active high IRQ ensures that the WM8350 interrupt handling does not spin when used with a SMDK6410 which has not had R20 removed and R21 fitted to connect EINT12 to the PMIC module rather thant the fixed regulators on the CPU module. Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: Ben Dooks <ben-linux@fluff.org>
-rw-r--r--arch/arm/mach-s3c6410/mach-smdk6410.c1
1 files changed, 1 insertions, 0 deletions
diff --git a/arch/arm/mach-s3c6410/mach-smdk6410.c b/arch/arm/mach-s3c6410/mach-smdk6410.c
index 466dee0954f..15f9c7a2a6c 100644
--- a/arch/arm/mach-s3c6410/mach-smdk6410.c
+++ b/arch/arm/mach-s3c6410/mach-smdk6410.c
@@ -303,6 +303,7 @@ static int __init smdk6410_wm8350_init(struct wm8350 *wm8350)
static struct wm8350_platform_data __initdata smdk6410_wm8350_pdata = {
.init = smdk6410_wm8350_init,
+ .irq_high = 1,
};
#endif