aboutsummaryrefslogtreecommitdiff
diff options
context:
space:
mode:
authorErik J. Staab <ejs@insightbb.com>2010-09-22 11:07:41 +0200
committerGreg Kroah-Hartman <gregkh@suse.de>2011-03-21 12:43:10 -0700
commit980a96c276db63b160ce7923806ce75c626d10fa (patch)
treeff393d9c53c4d7fa5e6b7baa40c6ecaebd4fa33f
parent8ecadb3f423ba4913d8c8ba6e98b3f78f271cc8f (diff)
ALSA: oxygen: fix analog capture on Claro halo cards
commit 0873a5ae747847ee55a63db409dff3476e45bcd9 upstream. On the HT-Omega Claro halo card, the ADC data must be captured from the second I2S input. Using the default first input, which isn't connected to anything, would result in silence. Signed-off-by: Erik J. Staab <ejs@insightbb.com> Signed-off-by: Clemens Ladisch <clemens@ladisch.de> Signed-off-by: Takashi Iwai <tiwai@suse.de> Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>
-rw-r--r--sound/pci/oxygen/oxygen.c4
1 files changed, 4 insertions, 0 deletions
diff --git a/sound/pci/oxygen/oxygen.c b/sound/pci/oxygen/oxygen.c
index acbedebcffd..39a0a3d15c5 100644
--- a/sound/pci/oxygen/oxygen.c
+++ b/sound/pci/oxygen/oxygen.c
@@ -543,6 +543,10 @@ static int __devinit get_oxygen_model(struct oxygen *chip,
chip->model.suspend = claro_suspend;
chip->model.resume = claro_resume;
chip->model.set_adc_params = set_ak5385_params;
+ chip->model.device_config = PLAYBACK_0_TO_I2S |
+ PLAYBACK_1_TO_SPDIF |
+ CAPTURE_0_FROM_I2S_2 |
+ CAPTURE_1_FROM_SPDIF;
break;
}
if (id->driver_data == MODEL_MERIDIAN ||