diff options
author | Tony Vroon <tony@linx.net> | 2011-06-20 22:11:11 +0100 |
---|---|---|
committer | Takashi Iwai <tiwai@suse.de> | 2011-06-21 07:18:36 +0200 |
commit | c933790614529c06b221f73ff36e2456aecee30d (patch) | |
tree | a9a9edfd7636096a6a59bfd1e10bb24655487fae | |
parent | 6f2e810ad5d162c2bfa063c1811087277b299e4e (diff) |
ALSA: hda - Remove ALC268 model override for CPR2000
The "diverse" Quanta ID 0x0763 is overridden to ALC268_ACER.
This keeps headphone automute and microphone input from operating
on at least one laptop from Opti Systems.
Without the override, the BIOS parser does a fine job setting the
card up and everything works.
Tested-By: Peter Schneider <e.at.chi.kaen@googlemail.com>
Signed-off-by: Tony Vroon <tony@linx.net>
Signed-off-by: Takashi Iwai <tiwai@suse.de>
-rw-r--r-- | sound/pci/hda/patch_realtek.c | 1 |
1 files changed, 0 insertions, 1 deletions
diff --git a/sound/pci/hda/patch_realtek.c b/sound/pci/hda/patch_realtek.c index c923b2cc9e5..475ed1e8ffc 100644 --- a/sound/pci/hda/patch_realtek.c +++ b/sound/pci/hda/patch_realtek.c @@ -13871,7 +13871,6 @@ static const struct snd_pci_quirk alc268_cfg_tbl[] = { SND_PCI_QUIRK(0x1043, 0x1205, "ASUS W7J", ALC268_3ST), SND_PCI_QUIRK(0x1170, 0x0040, "ZEPTO", ALC268_ZEPTO), SND_PCI_QUIRK(0x14c0, 0x0025, "COMPAL IFL90/JFL-92", ALC268_TOSHIBA), - SND_PCI_QUIRK(0x152d, 0x0763, "Diverse (CPR2000)", ALC268_ACER), SND_PCI_QUIRK(0x152d, 0x0771, "Quanta IL1", ALC267_QUANTA_IL1), {} }; |